Appendix H
Appendix H
Procedure to Configure Remote Track & Hold Card for Voltage Input.
The Remote Track & Hold Card (7-00844A) - assembly 7-00839A- is factory shipped to input a 0-20
or 4-20 analog value in milliampere form. The following procedures configure the circuit board (see
Figure H1) to operate with a voltage input of 0-1VDC, 0-5 VDC, or 0-10 VDC.
Figure H1 - Configuring Remote Track & Hold Board for Voltage Input
SENTRY Equipment Corp • P. O. Box 127 • Oconomowoc, WI 53066 • 262/567-7256 • FAX: 262/567-4523
Web: www.sentry-equip.com • e-mail: [email protected]